ocumentation box, including a reference to the section of the NIR where more detailed information can be found.
L25 • Use this documentation box for providing clarification on emission recovery, oxidation, destruction and/or transformation, and provide a reference to the section of the NIR where more detailed information can be found.
L26 2.C Metal Production:A surrogate method has been used to estimate AD for limestone and dolomite use. Because the use of limestone and dolomite is related to iron and steel production, the trend for iron production was used to estimate AD for limestone and dolomite use.
L27 2.C.3 Aluminium Production:AD: Specify the activity data used in order to make the choice of emission factor more transparent and to facilitate comparisons of implied emission factors. Emissions: Under Emissions the final emissions (after subtracting the amounts of emission recovery, oxidation, destruction or transformation) should be reported. Recovery: Amount of emission recovery, oxidation, destruction or transformation.IEF: The IEFs are estimated on the basis of gross emissions as follows: IEF = (emissions plus amounts recovered, oxidized, destroyed or transformed) / activity data.
L28 2.C.3 Aluminium Production/2011:CWPB technology type
Table2(II).E
L1 TABLE 2(II).E SECTORAL BACKGROUND DATA FOR INDUSTRIAL PROCESSES Inventory 2011
L2 Production of Halocarbons and SF6 Submission 2013 v2.2
L3 (Sheet 1 of 1) ROMANIA
L5 GREENHOUSE GAS SOURCE AND SINK CATEGORIES ACTIVITY DATA IMPLIED EMISSION FACTORS(2) EMISSIONS
L6 Emissions(3) Recovery(4)
L7 Description (1) (t) (kg/t) (t)
L8 E. Production of Halocarbons and SF6
L9 1. By-product Emissions
L10 Production of HCFC-22
L11 HFC-23 (specify) NO NO NO NO
L12 Other (specify activity and chemical)
L13 Other non-specified
L14 2. Fugitive Emissions (specify activity and chemical)
L15 HFCs NA,NO
L16 HFC-23 NO
L17 HFC-32 NO
L18 HFC-41 NO
L19 HFC-43-10-mee NO
L20 HFC-125 NO
L21 HFC-134 NO
L22 HFC-134a NO
L23 HFC-152a NO
L24 HFC-143 NO
L25 HFC-143a NO
L26 HFC-227ea NO
L27 HFC-236fa NO
L28 HFC-245ca NO
L29 Unspecified mix of HFCs NO
L30 PFCs NA,NO
L31 CF4 NO
L32 C2F6 NO
L33 C3F8 NO
L34 C4F10 NO
L35 c-C4F8 NO
L36 C5F12 NO
L37 C6F14 NO
L38 Unspecified mix of PFCs NO
L39 SF6 NO
L40 Other non-specified
L41 HFCs NO
L42 HFC-23 NO
L43 HFC-32 NO
L44 HFC-41 NO
L45 HFC-43-10-mee NO
L46 HFC-125 NO
L47 HFC-134 NO
L48 HFC-134a NO
L49 HFC-152a NO
L50 HFC-143 NO
L51 HFC-143a NO
L52 HFC-227ea NO
L53 HFC-236fa NO
L54 HFC-245ca NO
L55 Unspecified mix of HFCs NO
L56 PFCs NO
L57 CF4 NO
L58 C2F6 NO
L59 C3F8 NO
L60 C4F10 NO
L61 c-C4F8 NO
L62 C5F12 NO
L63 C6F14 NO
L64 Unspecified mix of PFCs NO
L65 SF6 NO
L66 3. Other (specify activity and chemical)
L67 HFCs NA,NO
L68 HFC-23 NO
L69 HFC-32 NO
L70 HFC-41 NO
L71 HFC-43-10-mee NO
L72 HFC-125 NO
L73 HFC-134 NO
L74 HFC-134a NO
L75 HFC-152a NO
L76 HFC-143 NO
L77 HFC-143a NO
L78 HFC-227ea NO
L79 HFC-236fa NO
L80 HFC-245ca NO
L81 Unspecified mix of HFCs NO
L82 PFCs NA,NO
L83 CF4 NO
L84 C2F6 NO
L85 C3F8 NO
L86 C4F10 NO
L87 c-C4F8 NO
L88 C5F12 NO
L89 C6F14 NO
L90 Unspecified mix of PFCs NO
L91 SF6 NO
L92 Other non-specified
L93 HFCs NO
L94 HFC-23 NO
L95 HFC-32 NO
L96 HFC-41 NO
L97 HFC-43-10-mee NO
L98 HFC-125 NO
L99 HFC-134 NO
L100 HFC-134a NO
L101 HFC-152a NO
L102 HFC-143 NO
L103 HFC-143a NO
L104 HFC-227ea NO
L105 HFC-236fa NO
L106 HFC-245ca NO
L107 Unspecified mix of HFCs NO
L108 PFCs NO
L109 CF4 NO
L110 C2F6 NO
L111 C3F8 NO
L112 C4F10 NO
L113 c-C4F8 NO
L114 C5F12 NO
L115 C6F14 NO
L116 Unspecified mix of PFCs NO
L117 SF6 NO
L119 (1) Specify the activity data used as shown in the examples within parentheses.
L120 (2) The implied emission factors (IEFs) are estimated on the basis of gross emissions as follows: IEF = (emissions + amounts recovered, oxidized, destroyed or transformed) / activity data.
L121 (3) Final emissions are to be reported (after subtracting the amounts of emission recovery, oxidation, destruction or transformation).
L122 (4) Amounts of emission recovery, oxidation, destruction or transformation.
L124 Documentation box:
L125 • Parties should provide detailed explanations on the industrial processes sector in Chapter 4: Industrial processes (CRF sector 2) of the NIR. Use this documentation box to provide references to relevant sections of the NIR if any additional information and/or further details are needed to understand the content of this table.
L126 • Where only aggregate figures for activity data are provided, e.g. due to reasons of confidentiality (see footnote 1 to table 2(II)), a note indicating this should be provided in this documentation box.
L127 • Where applying Tier 2 and country-specific methods, specify any other relevant activity data used in this documentation box, including a reference to the section of the NIR where more detailed information can be found.
L129 • Use this documentation box for providing clarification on emission recovery, oxidation, destruction and/or transformation, and provide a reference to the section of the NIR where more detailed information can be found.
Table2(II).Fs1
L1 TABLE 2(II).F SECTORAL BACKGROUND DATA FOR INDUSTRIAL PROCESSES Inventory 2011
L2 Consumption of Halocarbons and SF6 Submission 2013 v2.2
L3 (Sheet 1 of 2) ROMANIA
L5 GREENHOUSE GAS SOURCE ACTIVITY DATA IMPLIED EMISSION FACTORS EMISSIONS
L6 AND SINK CATEGORIES Amount of fluid Product manufacturing factor Product life factor Disposal loss factor From manufacturing From stocks From disposal
L7 Filled into new manufactured products In operating systems (average annual stocks) Remaining in products at decommissioning
L8 (t) (% per annum) (t)
L9 1. Refrigeration(1)
L10 Air Conditioning Equipment
L11 Domestic Refrigeration
(please specify chemical)(1)
L12 C5F12 NO NO NO NA NA NA NO NO NO
L13 C6F14 NO NO NO NA NA NA NO NO NO
L14 CF4 NO NO NO NA NA NA NO NO NO
L15 HFC-125 IE IE IE NA NA NA IE IE IE
L16 HFC-134 IE IE IE NA NA NA IE IE IE
L17 HFC-134a IE IE IE NA NA NA IE IE IE
L18 HFC-143 IE IE IE NA NA NA IE IE IE
L19 HFC-143a IE IE IE NA NA NA IE IE IE
L20 HFC-152a IE IE IE NA NA NA IE IE IE
L21 HFC-23 IE IE IE NA NA NA IE IE IE
L22 HFC-32 IE IE IE NA NA NA IE IE IE
L23 HFC-41 IE IE IE NA NA NA IE IE IE
L24 Commercial Refrigeration
L25 C5F12 NO NO NO NA NA NA NO NO NO
L26 HFC-125 IE IE IE NA NA NA IE IE IE
L27 HFC-134 IE IE IE NA NA NA IE IE IE
L28 HFC-134a IE IE IE NA NA NA IE IE IE
L29 HFC-143 IE IE IE NA NA NA IE IE IE
L30 HFC-143a IE IE IE NA NA NA IE IE IE
L31 HFC-152a IE IE IE NA NA NA IE IE IE
L32 HFC-227ea IE IE IE NA NA NA IE IE IE
L33 HFC-23 IE IE IE NA NA NA IE IE IE
L34 HFC-236fa IE IE IE NA NA NA IE IE IE
L35 HFC-32 IE IE IE NA NA NA IE IE IE
L36 HFC-41 IE IE IE NA NA NA IE IE IE
L37 HFC-43-10 mee IE IE IE NA NA NA IE IE IE
L38 Transport Refrigeration
L39 C5F12 NO NO NO NA NA NA NO NO NO
L40 HFC-125 IE IE IE NA NA NA IE IE IE
L41 HFC-134 IE IE IE NA NA NA IE IE IE
L42 HFC-134a IE IE IE NA NA NA IE IE IE
L43 HFC-143 IE IE IE NA NA NA IE IE IE
L44 HFC-143a IE IE IE NA NA NA IE IE IE
L45 HFC-23 IE IE IE NA NA NA IE IE IE
L46 HFC-32 IE IE IE NA NA NA IE IE IE
L47 Industrial Refrigeration
L48 C4F10 NO NO NO NA NA NA NO NO NO
L49 C5F12 NO NO NO NA NA NA NO NO NO
L50 HFC-125 IE IE IE NA NA NA IE IE IE
L51 HFC-134 IE IE IE NA NA NA IE IE IE
L52 HFC-134a IE IE IE NA NA NA IE IE IE
L53 HFC-143 IE IE IE NA NA NA IE IE IE
L54 HFC-143a IE IE IE NA NA NA IE IE IE
L55 HFC-152a IE IE IE NA NA NA IE IE IE
L56 HFC-227ea IE IE IE NA NA NA IE IE IE
L57 HFC-23 IE IE IE NA NA NA IE IE IE
L58 HFC-236fa IE IE IE NA NA NA IE IE IE
L59 HFC-32 IE IE IE NA NA NA IE IE IE
L60 HFC-41 IE IE IE NA NA NA IE IE IE
L61 HFC-43-10 mee IE IE IE NA NA NA IE IE IE
L62 SF6 NO NO NO NA NA NA NO NO NO
L63 Stationary Air-Conditioning
L64 C5F12 NO NO NO NA NA NA NO NO NO
L65 HFC-125 IE IE IE NA NA NA IE IE IE
L66 HFC-134 IE IE IE NA NA NA IE IE IE
L67 HFC-134a IE IE IE NA NA NA IE IE IE
L68 HFC-143 IE IE IE NA NA NA IE IE IE
L69 HFC-143a IE IE IE NA NA NA IE IE IE
L70 HFC-152a IE IE IE NA NA NA IE IE IE
L71 HFC-227ea IE IE IE NA NA NA IE IE IE
L72 HFC-23 IE IE IE NA NA NA IE IE IE
L73 HFC-236fa IE IE IE NA NA NA IE IE IE
L74 HFC-32 IE IE IE NA NA NA IE IE IE
L75 HFC-41 IE IE IE NA NA NA IE IE IE
L76 HFC-43-10 mee IE IE IE NA NA NA IE IE IE
L77 Mobile Air-Conditioning
L78 C5F12 NO NO NO NA NA NA NO NO NO
L79 CF4 NO NO NO NA NA NA NO NO NO
L80 HFC-125 IE IE IE NA NA NA IE IE IE
L81 HFC-134 IE IE IE NA NA NA IE IE IE
L82 HFC-134a IE IE IE NA NA NA IE IE IE
L83 HFC-143a IE IE IE NA NA NA IE IE IE
L84 HFC-227ea IE IE IE NA NA NA IE IE IE
L85 HFC-23 IE IE IE NA NA NA IE IE IE
L86 HFC-32 IE IE IE NA NA NA IE IE IE
L87 HFC-41 IE IE IE NA NA NA IE IE IE
L88 2. Foam Blowing(1)
L89 Hard Foam
L90 Soft Foam
L92 (1) Under each of the listed source categories, specify the chemical consumed (e.g. HFC-32) as indicated under category Domestic Refrigeration; use one row per chemical.
L93 Note: This table provides for reporting of the activity data and emission factors used to calculate actual emissions from consumption of halocarbons and SF6 using the "bottom-up approach" (based on the total stock of equipment and estimated emission rates from this equipment). Some Parties may prefer to estimate actual emissions following the alternative "top-down approach" (based on annual sales of equipment and/or gas). Those Parties should indicate the activity data used and provide any other information needed to understand the content of the table in the documentation box at the end of sheet 2 to this table, including a reference to the section of the NIR where further details can be found. Those Parties should provide the following data in the NIR:
L94 1. the amount of fluid used to fill new products,
L95 2. the amount of fluid used to service existing products,
L96 3. the amount of fluid originally used to fill retiring products (the total nameplate capacity of retiring products),
L97 4. the product lifetime, and
L98 5. the growth rate of product sales, if this has been used to calculate the amount of fluid originally used to fill retiring products.
L99 In the NIR, Parties may provide alternative formats for reporting equivalent information with a similar level of detail.
Table2(II).Fs2
L1 TABLE 2(II).F SECTORAL BACKGROUND DATA FOR INDUSTRIAL PROCESSES Inventory 2011
L2 Consumption of Halocarbons and SF6 Submission 2013 v2.2
L3 (Sheet 2 of 2) ROMANIA
L5 GREENHOUSE GAS SOURCE ACTIVITY DATA IMPLIED EMISSION FACTORS EMISSIONS
L6 AND SINK CATEGORIES Amount of fluid Product manufacturing factor Product life factor Disposal loss factor From manufacturing From stocks From disposal
L7 Filled into new manufactured products In operating systems (average annual stocks) Remaining in products at decommissioning
L8 (t) (% per annum) (t)
L9 3. Fire Extinguishers
(please specify chemical)(1)
L10 4. Aerosols (1)
L11 Metered Dose Inhalers
L12 Other
L13 5. Solvents (1)
L14 6. Other applications using ODS(2) substitutes (1)
L15 7. Semiconductor Manufacture (1)
L16 8. Electrical Equipment(1)
L17 9. Other (please specify)(1)
L18 Other non-specified
L19 HFC-125 42.708022 NO NO 50 NA NA 21.354011 NO NO
L20 HFC-134 NO NO NO NA NA NA NO NO NO
L21 HFC-134a 100.969492 NO NO 50 NA NA 50.484746 NO NO
L22 HFC-143a 37.929176 NO NO 50 NA NA 18.964588 NO NO
L23 HFC-152a 0.03364 NO NO 50 NA NA 0.01682 NO NO
L24 HFC-32 9.05047 NO NO 50 NA NA 4.525235 NO NO
L25 SF6 0.156 NO NO 50 NA NA 0.078 NO NO
L27 (1) Under each of the listed source categories, specify the chemical consumed (e.g. HFC-32) as indicated under category Fire Extinguishers; use one row per chemical.
L28 (2) ODS: ozone-depleting substances.
L30 Documentation box:
L31 • Parties should provide detailed explanations on the industrial processes sector in Chapter 4: Industrial processes (CRF sector 2) of the NIR. Use this documentation box to provide references to relevant sections of the NIR if any additional information and/or further details are needed to understand the content of this table.
L33 • Where only aggregate figures for activity data are provided, e.g. due to reasons of confidentiality (see footnote 1 to table 2(II)), a note indicating this should be provided in this documentation box.
L34 • With regard to data on the amounts of fluid that remained in retired products at decommissioning, use this documentation box to provide a reference to the section of the NIR where information on the amount of the chemical recovered (recovery efficiency) and other relevant information used in the emission estimation can be found.
L35 • Parties that estimate their actual emissions following the alternative top-down approach might not be able to report emissions using this table. As indicated in the note to sheet 1 of this table, Parties should in these cases provide, in the NIR, alternative formats for reporting equivalent information with a similar level of detail. References to the relevant section of the NIR should be provided in this documentation box.
L36 2.IIA.F.1.2 Commercial Refrigeration:Under each of the souce categories in the navigation tree, specify the chemical consumed using the "Add gas" option.As stated in the UNFCCC reporting guidelines, Parties should report actual emissions of HFCs, PFCs and SF6, where data are available, providing disaggregated data by chemical and source category in units of mass and in CO2 equivalent. Parties reporting actual emissions should also report potential emissions for the sources where the concept of potential emissions applies, for reasons of transparency and comparability. Gases with GWP values not yet agreed upon by the COP should be reported in Table 9 (b). In accordance with the UNFCCC reporting guidelines, HFC and PFC emissions should be reported for each relevant chemical. However, if it is not possible to report values for each chemical (i.e. mixtures, confidential data, lack of disaggregation), these could be reported under "Unspecified mix of ..." for HFCs and PFCs, respectively.
L37 Note that the unit used for these estimates is Gg of CO2 equivalent.
L38 2.IIA.F.2.1 Hard Foam/2011:According to the questionnaires received from the operators it was no Halocarbons and SF6 consumption recorded.
L39 2.IIA.F.2.2 Soft Foam/2011:According to the questionnaires received from the operators it was no Halocarbons and SF6 consumption recorded.
L40 2.F.3 Fire Extinguishers:Under each of the souce categories in the navigation tree, specify the chemical consumed using the "Add gas" option.As stated in the UNFCCC reporting guidelines, Parties should report actual emissions of HFCs, PFCs and SF6, where data are available, providing disaggregated data by chemical and source category in units of mass and in CO2 equivalent. Parties reporting actual emissions should also report potential emissions for the sources where the concept of potential emissions applies, for reasons of transparency and comparability. Gases with GWP values not yet agreed upon by the COP should be reported in Table 9 (b). In accordance with the UNFCCC reporting guidelines, HFC and PFC emissions should be reported for each relevant chemical. However, if it is not possible to report values for each chemical (i.e. mixtures, confidential data, lack of disaggregation), these could be reported under "Unspecified mix of ..." for HFCs and PFCs, respectively. Note that th
L41 e unit used for these estimates is Gg of CO2 equivalent.
L42 2.IIA.F.4.1 Metered Dose Inhalers/2011:According to the questionnaires received from the operators it was no Halocarbons and SF6 consumption recorded.
L43 2.IIA.F.4.2 Other/2011:According to the questionnaires received from the operators it was no Halocarbons and SF6 consumption recorded.
Table3
L1 TABLE 3 SECTORAL REPORT FOR SOLVENT AND OTHER PRODUCT USE Inventory 2011
L2 (Sheet 1 of 1) Submission 2013 v2.2
L3 ROMANIA
L5 GREENHOUSE GAS SOURCE AND SINK CATEGORIES CO2 N2O NMVOC
L6 (Gg)
L7 Total Solvent and Other Product Use 125.61413333333 NE 50.838
L8 A. Paint Application 10.1728 3.264
L9 B. Degreasing and Dry Cleaning 26.818916666667 NE 8.605
L10 C. Chemical Products, Manufacture and Processing NO 10.534
L11 D. Other 88.622416666667 NE 28.435
L12 1. Use of N2O for Anaesthesia NE
L13 2. N2O from Fire Extinguishers NE
L14 3. N2O from Aerosol Cans NE
L15 4. Other Use of N2O NE
L16 5. Other (as specified in table 3.A-D) 88.622416666667 NE 28.435
L17 Other solvent use 88.622416666667 NE 28.435
L19 Note: The quantity of carbon released in the form of NMVOCs should be accounted for in both the NMVOC and the CO2 columns. The quantites of NMVOCs should be converted into
L20 CO2 equivalent emissions before being added to the CO2 amounts in the CO2 column.
L22 Documentation box:
L23 • Parties should provide detailed explanations about the Solvent and Other Product Use sector in Chapter 5: Solvent and Other Product Use (CRF sector 3) of the NIR. Use this documentation box to provide references to relevant sections of the NIR if any additional information and/or further details are needed to understand the content of this table.
L24 • The IPCC Guidelines do not provide methodologies for the calculation of emissions of N2O from Solvent and Other Product Use. If reporting such data, Parties should provide in the NIR additional information (activity data and emission fac
← Înapoi la începutul extrasului